The Energy Use Implications of Design Choices in Commercial Buildings

Loading...
Thumbnail Image

Date

Authors

Kelsey, Jim

Advisors

License

DOI

Type

Journal Title

Journal ISSN

Volume Title

Publisher

University of Wisconsin-Madison

Grantor

Abstract

The process of designing a heating and cooling system for a commercial building usually proceeds from building design to design of an HVAC system that can meet the loads in the building. The purpose of this thesis is to focus instead on what can be done to minimize buildings loads, by making the best design choices. Wisconsin and other states are currently in the process of adopting their building energy codes to conform to ASHRAE/EIS standard 90.1-1989. The Energy Policy Act of 1992 requires that each state develop a commercial building code that is at least as stringent as this standard. This thesis investigates the effect of these revised codes on the energy use of new buildings. A case study of two common building types is used to quantify the effect of the codes on building loads. The thesis is a case study of two commercial buildings; using an office building and a retail building. These types of buildings were chosen because, together, they make up a large portion of the energy consumption and peak demand in the commercial building stock. For each of the buildings, TRNSYS computer simulations were used to estimate the energy use in the building. TRNSYS decks were created from data gathered from building plans and site visits. The computer simulations were validated using monthly energy bills from the two buildings. Computer simulations were used to estimate the effect of compliance to the ASHRAE standard on the energy use of the buildings. The building models were modified to include the addition of insulation to roofs, walls and building perimeters that would be required by the code. A life-cycle savings method was used in conjunction with the building models to determine what level of insulation would be the most cost effective design for the buildings. These optimal levels were compared to the ASHRAE required amount of insulation for five cities in the U.S. The energy and cost savings resulting from meeting the prescriptive version of the ASHRAE Standard 90.1 were found to be significant. In both of the buildings studied, building owners would have saved money had the buildings been built to comply with the standard. The simple payback period for individual measures required by the code varied over a wide range. Some measures would have paid for themselves instantly, in cooling equipment cost savings. Other measures had payback periods up to 24 years. Taking all the required measures together yielded payback periods of 6 to 8 years. Two daylighting strategies were also evaluated using the retail building model. The TRNSYS deck and building input description were modified to simulate the addition of skylights and sawtooth roof monitors to the building. The building models included both the direct effects of lighting energy savings, and the indirect effects on heating and cooling loads in the building. A life-cycle cost analysis was conducted to determine the optimal area of skylights or monitors to add, and the energy and cost savings associated with each. The daylighting measures offered payback periods equal to or less than the insulation measures required by ASHRAE Standard 90.1. Daylighting measures yielded cooling energy savings, and decreased electricity bills, while ASHRAE code compliance mainly provided energy savings from heating loads met with natural gas. Should energy planners want to focus more on electricity savings rather than natural gas, one way to do it would be to facilitate the installation of more daylighting in commercial buildings.

Description

Under the supervision of Professors John Mitchell and William Beckman; 124pp.

Related Material and Data

Citation

Kelsey, J. (1996). The Energy Use Implications of Design Choices in Commercial Buildings. Master's Thesis, University of Wisconsin-Madison.

Sponsorship

Sponsored by ASHRAE, The Energy Center of Wisconsin, and The American Public Power Association.

Endorsement

Review

Supplemented By

Referenced By