Impact on a Utility of an Ensemble of Solar Domestic Hot Water Systems
| dc.contributor.author | Cragen, Keary E. | en_US |
| dc.date.accessioned | 2007-05-14T14:41:38Z | |
| dc.date.available | 2007-05-14T14:41:38Z | |
| dc.date.issued | 1994 | en_US |
| dc.description | Under the supervision of Professors William Beckman and Sanford Klein; 254pp. | en_US |
| dc.description.abstract | The benefits to a utility and to the environment of the installation of a large number of solar domestic hot water (SDHW) systems are identified and quantified. The environmental benefits of SDHW systems include reduced energy use, reduced electrical demand, and reduced pollution. Utilities use various forms of power generation to meet the system load, beginning with the plant with the lowest operating costs. Each of these plants incurs a certain cost to the utility and to the environment. Coal, oil, and natural gas plants release varying levels of carbon dioxide, sulfur dioxide, oxides of nitrogen, and particulates. The cost to the environment for these pollutants can be converted into $/ton produced. Using a marginal plant analysis based on a least cost production model, a utility's avoided emissions, avoided costs, and capacity contribution from the installation of many SDHW systems has been evaluated and the impact of many solar systems on the utility has been quantified. The avoided emissions, capacity contribution, energy and demand savings were evaluated using the power generation schedules, emissions data and annual hourly load profiles from local utilities. It is shown is that power plant maintenance and outage scheduling significantly effect the amount and type of airborne pollutants at the margin during a utility's off-peak periods. SDHW systems are thereby found to be beneficial during both peak periods and periods of scheduled maintenance from an environmental point of view. As a specific example, each six square meter solar water heating system can save annually: 3559 kWh of the energy, 0.66 kW of peak demand, and over four tons of pollution (7727 # CO2, 51 # SO2, 0.11 # N2O, 17 # NOX, 0.13 # CH4, and 1.1 # particulates) for a Wisconsin utility. (Based on 5928 kWh annual energy requirements of a conventional 52 gallon electric system resulting in over six tons of airborne pollutants: 12705 # CO2, 80.78 # SO2, 0.180 # N2O, 28.35 # NOX, 0.200 # CH4, 1.820 # particulates.) | en_US |
| dc.description.sponsorship | Sponsored by the Wisconsin Energy Bureau under Contract No. 84067 and co-funded by the United States Department of Energy. | en_US |
| dc.format.extent | 82168 bytes | |
| dc.format.extent | 72488 bytes | |
| dc.format.extent | 215068 bytes | |
| dc.format.extent | 51176 bytes | |
| dc.format.extent | 751640 bytes | |
| dc.format.extent | 58060 bytes | |
| dc.format.extent | 1527684 bytes | |
| dc.format.extent | 265520 bytes | |
| dc.format.extent | 443476 bytes | |
| dc.format.extent | 530555 bytes | |
| dc.format.extent | 193098 bytes | |
| dc.format.extent | 169436 bytes | |
| dc.format.extent | 1543764 bytes | |
| dc.format.extent | 791503 bytes | |
| dc.format.extent | 2923425 bytes | |
| dc.format.extent | 63815 bytes | |
| dc.format.extent | 82631 bytes | |
| dc.format.extent | 739646 bytes | |
| dc.format.extent | 92212 bytes | |
| dc.format.extent | 93617 bytes | |
| dc.format.extent | 42197 bytes | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/octet-stream | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | en_US |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Cragen, K.E. (1994). Impact on a Utility of an Ensemble of Solar Domestic Hot Water Systems. Master's Thesis, University of Wisconsin-Madison. | en_US |
| dc.identifier.uri | http://digital.library.wisc.edu/1793/7857 | |
| dc.publisher | University of Wisconsin-Madison | en_US |
| dc.subject | Thesis (M.S.)--University of Wisconsin--Madison, 1994. | en_US |
| dc.subject | University of Wisconsin--Madison. College of Engineering. | en_US |
| dc.subject | Dissertations Academic Mechanical Engineering. | en_US |
| dc.title | Impact on a Utility of an Ensemble of Solar Domestic Hot Water Systems | en_US |