Determining a temperature-density relationship after completed rolling of HMA

dc.contributor.authorRussell, Jeffrey
dc.contributor.authorLoh, Ssu-Weh
dc.contributor.authorSchoenfelder, Stephen
dc.contributor.authorHanna, Awad
dc.contributor.authorBahia, Hussain
dc.date.accessioned2007-01-10T14:38:26Z
dc.date.available2007-01-10T14:38:26Z
dc.date.issued2002-01
dc.description100 p.
dc.description.abstractDuring the past few years, the implementation of the nuclear gauge method of testing hot mix asphalt for desired compaction has proven a on-destructive and timesaving option. However, discrepancies between contractors' and WisDOT readings have led to this research which serves to investigate the relationship between the temperature and density of newly placed hot mix asphalt. The theory states that as asphalt cools, it becomes denser. Hence, if a nuclear gauge is used to measure density after the asphalt has been allowed to cool, it should record a higher reading than when the asphalt was measured just after cold rolling the previous day. This research investigation has found a model that has not reinforced this theory. The research has shown that testing a road for density the morning following paving will not result in a significant difference in density than if it is tested the same day of paving.en
dc.description.abstractThis research investigates the range of load-carrying capability, in terms of resilient modulus (M sub R), of crushed aggregate base course in Wisconsin and how variables, such as physical characteristics, material type, source lithology and regional factors influence M sub R. Testing was conducted on 37 aggregate sources and the results statistically analyzed to look for correlations between M sub R and these variables and to determine if they could be used to predict M sub R. Results showed that M sub R did not differ between gravel pit and quarry groups and that carbonate quarries generally gave significantly higher M sub R values than Precambrian, felsic-plutonic quarries. Changing gradation of base course from a given source affected M sub R test results, but not consistently or predictably. Certain physical parameters, were found that influence M sub R in some of the geologic subsets. However, none of the correlations were strong enough to predict M sub R with sufficient confidence. The test data will provide a base of information that will be useful when the Wisconsin Department of Transportation adopts a mechanistic-empirical pavement design process.
dc.description.sponsorshipWisconsin Department of Transportationen
dc.format.extent916678 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.otherTRID: 00980091
dc.identifier.otherOCLC: 50933196
dc.identifier.urihttp://digital.library.wisc.edu/1793/6851
dc.language.isoen_US
dc.publisherWisconsin Highway Research Program
dc.relation.ispartofseriesWHRP;02-001
dc.subjectTemperatureen
dc.subjectDensityen
dc.subjectHot mix paving mixturesen
dc.titleDetermining a temperature-density relationship after completed rolling of HMAen
dc.typeTechnical reporten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
WHRP 02 01- Determining a Temperature-Density Relationship After Completed Rolling of HMA.pdf
Size:
895.19 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.95 KB
Format:
Item-specific license agreed upon to submission
Description: