Design and Development of a 7 DOF Robot with Ergonomic Shoulder for Upper Limb Rehabilitation

dc.contributor.advisorMohammad Habibur Rahman
dc.contributor.committeememberIlya V. Avdeev
dc.contributor.committeememberWoojin Chang
dc.contributor.committeememberIstvan Lauko
dc.contributor.committeememberInga Wang
dc.creatorIslam, Md Rasedul
dc.date.accessioned2025-01-16T18:30:07Z
dc.date.issued2020-12-01
dc.description.abstractWith the increase of stroke patients, the number of upper limb dysfunction is increasing day by day. Robotic intervention in upper limb (UL) rehabilitation of post-stroke patients has gained much traction in recent years. Though many research groups have developed exoskeletons, existing exoskeletons have limitations in both hardware design and control approaches. In most cases, rehabilitative robotic devices have not considered the movement of the shoulder joint’s center (center of glenohumeral joint); however, this movement leads to misalignment between human joints and robot joints, which is undesirable in any circumstances. To ensure better human-robot interaction (HRI), allowing mobility of shoulder joint’s (glenohumeral joint) center of rotation without reducing the range of motion (ROM) remains a great challenge for UL exoskeleton researchers. Furthermore, being able to function as end-effector setup and exoskeleton setup (i.e., dual functionality) is a crucial need for exoskeletons to provide joint-based exercises and end-point exercises depending on the patient’s condition, impairment level, and stage of rehabilitation. Moreover, interaction forces between user and robot have largely been ignored in passive rehabilitation. Force can also be used in performing active exercises. In this research, an upper limb robotic exoskeleton has been designed and developed to provide better HRI, dual functionality, safe and effective, and patient-tailored therapy. The experimental results have shown its potential to be used with stroke-patients in a hospital setting.
dc.description.embargo2022-12-23
dc.embargo.liftdate2022-12-23
dc.identifier.urihttp://digital.library.wisc.edu/1793/86963
dc.relation.replaceshttps://dc.uwm.edu/etd/2526
dc.subjectErgonomic Shoulder
dc.subjectExoskeleton
dc.subjectFrontal Mechanism
dc.subjectRehabilitation
dc.subjectRobot
dc.subjectSagittal Mechanism
dc.titleDesign and Development of a 7 DOF Robot with Ergonomic Shoulder for Upper Limb Rehabilitation
dc.typedissertation
thesis.degree.disciplineEngineering
thesis.degree.grantorUniversity of Wisconsin-Milwaukee
thesis.degree.nameDoctor of Philosophy

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Islam_uwm_0263D_12890.pdf
Size:
11.53 MB
Format:
Adobe Portable Document Format
Description:
Main File