Evaluation of energy expenditure on the Woodway curve treadmill
| dc.contributor.advisor | Porcari, John P. | |
| dc.contributor.author | Maerz, Lance T. | |
| dc.date.accessioned | 2013-07-22T18:34:47Z | |
| dc.date.available | 2013-07-22T18:34:47Z | |
| dc.date.issued | 2013-05 | |
| dc.description.abstract | This study was designed to 1) compare the caloric expenditure values displayed on the Curve's console to directly measured values, and 2) if there was a significant difference between displayed and measured values, to develop a regression equation to more accurately predict energy expenditure on the Curve. Fifty-five volunteers (27 male and 28 female) walked or ran on the Curve treadmill at four different speeds (between 2-8 mph) for five minutes at each speed. The caloric expenditure values displayed on the Curve's console were recorded and compared to measured calories using a Jaeger Oxycon portable metabolic analyzer. Across the speeds tested, the Curve console systematically overestimated measured caloric expenditure by 67-117%. | en |
| dc.identifier.uri | http://digital.library.wisc.edu/1793/66175 | |
| dc.language.iso | en_US | en |
| dc.subject | Athletic performance | en |
| dc.subject | Exercise tests | en |
| dc.subject | Physical fitness | en |
| dc.title | Evaluation of energy expenditure on the Woodway curve treadmill | en |
| dc.type | Thesis | en |
| thesis.degree.discipline | Clinical Exercise Physiology | en |
| thesis.degree.level | MS | en |